Firmware info + supported devices list
Firmware information for P44-DSB-E
Current version |
---|
2.8.0 – show release notes |
Compatibility list for P44-DSB-E
Functionality | Profile(s) | Status |
---|---|---|
EnOcean | ||
Temperature sensors, various ranges | A5-02-xx | full Digital Strom dSS level integration All indoor temperature sensors can be used in the Heating Controller app. All sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
Indoor temperature / humidity sensors | A5-04-01 | full Digital Strom dSS level integration Only temperature can be used in heating app. Humitity sensor value can be processed using P44-DSB Evaluator Devices to trigger signals to the dSS when reaching threshold values. The humidity sensor value is also accessible via the dSS JSON API. |
Outdoor temperature / humidity sensors | A5-04-02 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
Temperature / humidity sensors | A5-04-03 | full Digital Strom dSS level integration |
Illumination sensors | A5-06-01..03 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
Illumination sensors | A5-06-04..05 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
Occupancy sensors | A5-07-01..02 | full Digital Strom dSS level integration |
Occupancy and illumination sensor | A5-07-03 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The illumination value is also accessible via the dSS JSON API. |
Light / temperature / motion / presence sensors | A5-08-01 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
CO sensor, with optional temperature sensor | A5-09-02 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
CO2 sensor, with optional humidity and temperature sensors | A5-09-04 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
Various Room control panels | A5-10-01..0D, -10..17, -22, -23 | full Digital Strom dSS level integration Temperature sensors can be used by Heating controller app. Sensor and control dial values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors and control dials are also accessible via the dSS JSON API. |
Energy meter | A5-12-01 | full Digital Strom dSS level integration The sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
Weather Station | A5-13-01/02 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. The DCF 77 clock features of certain weather stations are not supported. |
Wind sensor | A5-13-07 | full Digital Strom dSS level integration Sensor values can be processed via dSS App States (user defined states) or using P44-DSB Evaluator Devices to trigger activities in the dSS when reaching threshold values. The values from sensors are also accessible via the dSS JSON API. |
Multi-function window and door contacts, glas breakage, lock state, supply voltage | A5-14-01...0A | full Digital Strom dSS level integration |
Heating valve actuator | A5-20-01 | full integration via task specific dSS apps Supported by digitalSTROM heating app. |
Heating valve actuator | A5-20-04 | full integration via task specific dSS apps Supported by digitalSTROM heating app. Advanced configuration options in this profile are only partially supported. |
Harvesting Heating valve actuator | A5-20-06 | full integration via task specific dSS apps Supported by digitalSTROM heating app. Advanced configuration options in this profile are only partially supported. |
Temperature and water sensor | A5-30-03 | full Digital Strom dSS level integration |
Central Control for Blinds | A5-38-08 | Integration planned for a future firmware release Blinds control with separate channels for position and angle, working with standard shadow behaviour in DS and the "window covering" profile in matter. |
Electronic switches and dimmers | D2-01-xx | full Digital Strom dSS level integration Output devices with one or multiple outputs. Each output appears as a separate device and can be used for switching or dimming lights or as a generic relay. |
Single button with battery indicator | D2-03-0A | full Digital Strom dSS level integration |
Blinds Control for Position and Angle | D2-05-xx | Integration planned for a future firmware release Blinds control with separate channels for position and angle, working with standard shadow behaviour in DS and the "window covering" profile in matter. |
Multisensor Window Handle | D2-06-xx | full Digital Strom dSS level integration Note: firmware before 2.0.0.3 only supports clicks for the buttons but no "dimming" (press and hold) because window handles do not report button release fast enough. From 2.0.0.3 onwards "dimming" works, however with a slightly longer delay than usual (~1 Second). |
Lock - Bolt and catch state | D2-07-00 | full Digital Strom dSS level integration |
Multichannel Temperature Sensor | D2-0A-00,01 | Integration planned for a future firmware release Temperature sensor usage is "undefined", which means not directly usable as room or outside temperature sensor. This is because devices using this profile are usually technical temperature sensors in heating/cooling systems and need to be processed by P44 evaluators or script before signalling to DS. |
Temperature / humidity sensor + smoke detector | D2-14-30 | full Digital Strom dSS level integration |
Temperature / humidity / illumination sensor | D2-14-40 | full Digital Strom dSS level integration |
1-3 phase AC current clamps | D2-32-xx | full low level integration, but device features accessible for app development only at this time Current values can be used in user defined states dS-app or P44-DSB evaluators No support yet (2018) in dS for using values for overall consumption measurement in the consumption dS app |
Single contact | D5-00-01 | full Digital Strom dSS level integration This is a generic contact profile in EnOcean, so it reports 1 for active and 0 for inactive contact. Please note that this is inverted compared to what digitalSTROM expects for window and door contacts (0 for closed window, 1 for open window). In this case, please use the "inverted" configuration (selectable in the info dialog of the contact in the P44-DSB Web-UI). |
Single one-way button | F6-01-01 | full Digital Strom dSS level integration |
Dual two-way rocker buttons | F6-02-xx | full Digital Strom dSS level integration |
Quad two-way rocker buttons | F6-03-xx | full Digital Strom dSS level integration |
Key card switch | F6-04-xx | full Digital Strom dSS level integration Usable in event responder |
Wind speed threshold detector | F6-05-00 | full Digital Strom dSS level integration |
Liquid Leakage detector | F6-05-01 | full integration via task specific dSS apps |
Smoke detectors like Eltako FRW or alphaEOS GUARD | F6-05-02 | full Digital Strom dSS level integration Only reporting of alarm and low battery supported, but no remote alarm reset or other functions (these are proprietary extensions of some manufacturers not available for generic integration) |
Window handles | F6-10-xx | full Digital Strom dSS level integration |
Controllable via RPS (F6-xx-xx) | RPS Aktor | DIY/Experimental, non-commercial integration in free / open source versions |
Custom devices implemented in p44script on-device | ||
custom devices implemented in p44script via web interface | p44script devices | full Digital Strom dSS level integration |
Philips hue | ||
hue tunable white (ambiance) lamp | ambiance | full Digital Strom dSS level integration |
hue color lamp | hue | full Digital Strom dSS level integration |
LivingColors mood light | LivingColors | full Digital Strom dSS level integration |
hue lux warm white lamp | lux | full Digital Strom dSS level integration |
- full / partial Digital Strom dSS level integration
- full / partial integration via task specific dSS apps
- full / partial low level integration, but device features accessible for app development only at this time
- Supported as beta version
- DIY/Experimental, non-commercial integration in free / open source versions
- Integration planned for a future firmware release
- Please Note: Older documentation may list EnOcean profiles A5-xx-xx as 07-xx-xx, D5-xx-xx as 06-xx-xx and F6-xx-xx as 05-xx-xx.